Medical product list Patient vacinity Understanding medical industry Engineering services Reference information  
Medical Product List Patient Vicinity
Legislation
Medical Industry
Understanding
Engineering
Services
Reference
Information
 
Medical Power Solutions

Medical Power Solutions

 

XP Power understands the challenges faced by medical device manufacturers due to legislation and market demands. Our products are designed to meet these challenges and provide cost-effective solutions for use in both the hospital and non-hospital environments. Understanding the requirements of our target customers has led to product features that are incorporated for a reason, such as class II approvals for homecare devices, highly efficient convection-cooled designs for low noise patient area devices and defibrillator-proof DC-DC converters for applied part applications.


Click here to view our Medical Power Solutions brochure.

 

 

Medical Product Overview

 
VEP VEP:
VEP08
AC-DC external power supply Product Info
8-24 Watts
Energy Star level V (8 & 15 W)
Class II construction
Low cost
Interchangeable input connectors
   

VEP15

AC-DC external power supply

Product Info

VEP24

AC-DC external power supply

Product Info
CU15-M CU15-M:
CU15-M
AC-DC power supply Product Info
15 Watts
Single output
Medical version
Low cost
Peak current capability
   
 
VCP VCP:
VCP15 AC-DC power supply Product Info
15/24 Watts
Output voltages from 3 to 24 V
PCB mounting
Open frame & encapsulated versions
No load input power <0.3 W
   

VCP24

AC-DC power supply

Product Info
PDM PDM30:

PDM30

AC-DC external power supply

Product Info
30 Watts
Single outputs from 12-48 VDC
4000 VAC isolation
Class II construction
High Efficiency
   
 
ECP ECP40:

ECP40

AC-DC power supply

Product Info
40 Watts
Low profile design
Single, dual & triple outputs
<0.3 W no load input power
IT& medical safety approvals
   
 
ECS ECS:

ECS25

AC-DC power supply

Product Info
25-100 Watts
Single outputs from 12-48 VDC
Convection-cooled
Class I & II construction
Low leakage current
   

ECS45

AC-DC power supply

Product Info

ECS100

AC-DC power supply

Product Info
AEM AEM60:

AEM60

AC-DC external power supply

Product Info
60 Watts
Single outputs from 5-48 VDC
4000 VAC isolation
Class II construction
High Efficiency
   
 
ECM ECM40-100:

ECM40-100

AC-DC power supply

Product Info
40-100 Watts
Medical & industrial approvals
Low leakage current
Level B conducted emissions
EN61000-3-2, -3 compliant
   
 
AMM AMM:

AMM90

AC-DC external power supply

Product Info
90-120 Watts
Worldwide medical approvals
Small size, high power density
Class I and II versions
Universal input
   

AMM120

AC-DC external power supply

Product Info
ECM140 ECM140:

ECM140

AC-DC power supply

Product Info
140 Watts
IT, industrial & medical approvals
Class I & II construction
Remote sense
5 V standby option
   
 
SDS SDS150-M:

SDS150-M

AC-DC power supply

Product Info
150 Watts
Single outputs from 12-24VDC
3" x 5" footprint
Convection-cooled
Worldwide medical approvals
   
 
CLC175-M CLC175-M:

CLC175-M

AC-DC power supply

Product Info
175 Watts
Medical Safety Approval
High Efficiency Resonant Topology
12 V Fan Output
Remote Sense
   
 
RCL175 RCL175:

RCL175

AC-DC power supply

Product Info
175 Watts
200 Watts peak rating
Up to 120 Watts convection-cooled
Class I & II approvals
Flexible design for modified standards
   
 
PBM PBM:

PBM200

AC-DC power supply

Product Info
200-300 Watts
Single, dual, triple & quad outputs
Worldwide medical approvals
Power fail detect & remote on/off
Universal AC input with active PFC
   

PBM300

AC-DC power supply

Product Info
CCM CCM250:

CCM250

AC-DC power supply

Product Info
250 Watts
Convection-cooled
300 W peak rating for 500 ms
Very high efficiency up to 95%
Class B conducted & radiated emissions
   
 
SMM SMM:

SMM

AC-DC power supply

Product Info
400 Watts
Low profile for 1U applications
Output voltages from 3.3 to 54 V
Optional current share & AC fail
Enclosed with internal fan & U-Channel versions
   
 
LP-MD LP-MD:

LP-MD

AC-DC configurable power

Product Info
250-450 Watts
Configurable for fast time-to-market
All outputs isolated
Low profile for 1U applications
Wide voltage adjustment range
   
 
MHP MHP650:

MHP650

AC-DC power supply

Product Info
650 Watts
Top fan & U-channel options
-20ºC to +70ºC operation
AC OK & remote on/off
Active current share
   
 
flexpower fleXPower:

fleXPower

AC-DC configurable power

Product Info
400-2400 Watts
Configurable for fast time-to-market
Flexible series and parallel capability
Output voltages up to 150 VDC
-20 ºC operation
   
 
JHM DC-DC Converters :

JHM

3-6 W Through hole mount

Product Info
1-6 Watts
International medical approvals
SIP & DIP packages
Up to 6000 VAC isolation
Low patient leakage current
   
 

Medical Power Supplies

 
Patient Vicinity Legislation  
Located in Europe, North America and Asia, our specialist medical technical sales teams offer a clear understanding of the legislation requirements of B, BF and CF classified equipment within the patient vicinity.

If the end equipment is within the patient vicinity, it must meet the isolation and leakage current requirements of IEC60601-1, or its relevant product specific standard, as well as any national deviations such as EN60601-1, UL60601-1 and CSA22.2 No. 601.1 M90. Our AC-DC power supplies provide the primary isolation barrier and the low earth-leakage required to meet these standards.

If the equipment has an applied part, BF or CF classified, an additional isolation barrier is required between the output of the power supply and the applied part and earth. This may be provided by an integral piece of the equipment design such as a non-conductive probe. Where an electrical connection is required we are able to offer suitable solutions for this purpose.

Generally, the patient vicinity is defined as the area where patients normally receive care. It is the space with surfaces likely to come in contact with the patient or an attendant who can touch the patient. It encloses a space within the room 1.83 m (6 ft) beyond the perimeter of the bed (examination table, chair, treatment booth or the like) in its intended location, and extending vertically 2.28 m (7.5 ft) above the floor.

Doctor


Medical Industry Understanding  

EMC Compliance

Our products undergo EMC testing to help us provide as much information as possible during design-in to ensure compliance with IEC60601-1-2. To aid compliance, EMC testing facilities within Europe and North America are available free of charge to customers.

Laboratory Environment Compliance

For equipment used within laboratory environments, compliance with IEC60950 is normally sufficient, involving less stringent isolation and leakage current requirements.

Isolation Barriers

The diagram below illustrates isolation for a typical medical device with an applied part. Two isolation barriers are required to ensure that the applied part is isolated from the ground and meets the patient leakage current limits during normal and single fault conditions. The primary isolation barrier for this type of equipment can be provided by an XP power supply, while the secondary isolation barrier is provided by another system component or XP solution.



Medical understanding


Engineering Services  
Off-the-shelf power supplies do not always meet the specific requirements of the target application. Many power systems require custom output voltage combinations, unique control / status signals and specific mechanical packaging for optimal performance and integration.

XP Engineering Services offers solutions in cases where applications cannot be fulfilled from our standard product range or where customers require integrated products. We offer the world’s widest standard product range, which provides us with the largest selection of power platforms from which we are able to quickly deliver modified standard power solutions.

Customer-specific power solutions are maintained under strict revision control and clearly defined by their specifications and assembly drawings. Close attention is paid to designing a product fit for purpose, ensuring conformance to the relevant industry and safety standards as well as meeting EMI, EMC and harmonic distortion levels.

With local engineering design teams in key regions throughout North America, Europe and the Far East, XP is the ideal source to develop your power solution. Our key skill sets include:

Design & Manufacturing Sites
European & North American design and manufacturing for low/medium volume
Far East manufacturing in China and Taiwan for medium/high volume
Mechanical Design Services
Custom enclosure design
Machined parts design and busbars
Solid prototype CAD modelling and photoquality rendering
Thermal modelling
Cable harness design
Eurocard, baseplate-cooled, racks and custom enclosures
Electrical Design Services
Circuit design and analysis
Hundreds of years of combined power design experience
Schematic capture and custom multi-level power PCB design
EMC/EMI analysis and testing
Customer circuit integration

Whatever the system’s power requirements, XP offers cost-effective, application-specific solutions designed to meet your electrical, mechanical, safety, EMC and thermal management requirements, while ensuring a fast time to market.

Engineering


Quick Reference Information  
Safety Approvals

IEC60601-1 Medical electrical equipment – Safety requirements for medical electrical systems.
   
National Deviations: EN60601-1: Europe
UL60601-1: USA
CSA 22.2 No 601.1: Canada
   
IEC60601-1-2 Medical electrical equipment – Electromagnetic compatibility – requirements and tests.
   
National Deviation: EN60601-1-2: Europe


Emission and Immunity Specifications

IEC55011/IEC55022 Limits for conducted and radiated emissions
IEC61000-3-2 Limits for harmonic current emissions
IEC61000-3-3 Limitation of voltage changes, voltage variations and flicker
IEC61000-4-2 Electrostatic discharge immunity
IEC61000-4-3 Radiated immunity
IEC61000-4-4 Electrical fast transient immunity
IEC61000-4-5 Electrical surge immunity
IEC61000-4-6 Conducted disturbance immunity
IEC61000-4-8 Immunity to power frequency magnetic field
IEC61000-4-11 Immunity to voltage dips, short interruptions and variations on supply line


Leakage Currents

Earth leakage = Current flowing in the earth conductor.
Enclosure leakage = Current flowing to earth via the patient from the enclosure.
Patient leakage = Current flowing to earth via the patient from an applied part.
Patient auxiliary = Patient auxiliary = Current flowing between two applied parts.


Leakage
Current
Type B Type BF Type CF
NC SFC NC SFC NC SFC
Earth Leakage
Current*
500 µA 1 mA 500 µA 1 mA 500 µA 1 mA
Enclosure Leakage
Current*
100 µA 500 µA 100 µA 500 µA 100 µA 500 µA
Patient Leakage
Current
100 µA 500 µA 100 µA 500 µA 10 µA 50 µA

NC = Normal Conditions SFC = Single Fault Conditions
*Patient care equipment maximum earth and enclosure leakage current for the US is 300 μA.
Figures quoted are for portable equipment.


Isolation and Separation

Insulation Type IEC60950 IEC60601-1
Air
Clearence
Creepage
Distance
Air
Clearence
Creepage
Distance
Basic or
Supplementary
2.0 2.2 2.5 4.0
Double or
Reinforced
4.0 6.4 5.0 8.0

All distances in mm. 250 VAC working voltage.


Insulation Type IEC60950 IEC60601-1
Test Voltage Test Voltage
Basic 1500 VAC 1500 VAC
Supplementary 1500 VAC 2500 VAC
Double or Reinforced 3000 VAC 4000 VAC


Insulation test voltages based on 250 VAC working voltage.

For more details about our custom power solutions - click here

A range of technical articles are also available here


Reference


Defence & Avionics Communications Medical

Industrial

Engineered Solutions